FSC SK ERP Description
E7h Bh 11
The initiator sent an Abort or Initiator Detected Error message
during a read operation and the command was aborted.
EAh 5h 4
Conflict between Density Code and Data Compression Page in
MODE SELECT.
EBh Bh 11 Operation illegal during write buffer sequence.
ECh 1h 10, 11
Log parameter overflow (a cumulative counter reached its
maximum value of all FFs).
FAh 4h 15 The CTS’s serial number is invalid or blank.
FCh 4h 15 Head sync value in EEPROM is out of range.
FDh 4h 15 The EEPROM contains meaningless information.
a
If the read-back-check criteria are not met for an LBOT or LBOP, filemark, setmark, or EOD block written to
tape, the CTS moves the tape backward and retries the operation 11 times. If the read-back-check criteria are
still not met, the CTS returns Check Condition status and these FSCs apply.
b
If the read-back-check criteria are not met for a data or short filemark block (that is, if the block is not perfect),
the block is rewritten. If rewrite activity is excessive, the CTS moves the tape backward, reads the tape to verify
that blocks are written, and then moves the tape backward again. It then performs a write splice operation and
rewrites the blocks. If the rewrite threshold is exceeded for any block, the CTS returns Check Condition status
with the sense key set to Medium Error (3h) and the FSC set to 9Eh. If the recovery splice operation cannot be
completed, the FSC is 9Dh.